Astm c31 free download






















Your Alert Profile lists the documents that will be monitored. You need to log in before adding standards to the monitoring service. Asm Printed and bound.

You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. In addition the electronic files may not be downloaded or distributed elsewhere over computer networks or otherwise. It is the responsibility of the user of this standard asfm establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked c Standards Subsctiption may be the perfect solution. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Since the test aztm performed with mortar, the results may not provide a direct correlation of how the fly ash or natural pozzolan will contribute to strength in concrete. Cylinder molds can be metal or plastic, so long as they are non-absorbent, non-reactive to concrete, and maintain their shape and dimensions under all conditions of use.

They must not leak when water is poured into them empty. Vibrators or rodding are entirely interchangeable, but vibrators must be used for slumps 1" or less. When planning to mold and cure concrete specimens, it is required that tests for slump, temperature, and air content be performed unless entrained air is not of concern to the project.

During initial curing, the cylinders must be stored in a temperature range from 60 - 80 degrees F in an environment that prevents moisture loss for up to 48 hours. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. This is a cloud services platform that we used to host our service.

When you are picking a place to make your cylinders, make sure it is in a level area that is free of debris, away from vibration, and away from moving vehicles and large construction equipment. Cylinders shall have free water maintained on their surfaces at all times and remain in a constant temperature of This supports the Maven widget and search functionality.

Protect the surfaces of both in the same manner the structure is protected, as best as possible. Warning— Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to exposed skin and tissue upon prolonged exposure. You could also use an air compressor to remove the mold quickly, using something to create a small hole at the bottom of the mold and blowing air through that.

When you sample the concrete, try to get your sample from the middle of the batch and not the first or last clumps of concrete, because the first or last portions may come out of the mixer slightly different from the rest of the batch.

For vibration, see 3B. This is used to provide data on traffic to our website, all personally identifyable data is anonymized. Work Item s — proposed revisions of this standard. If steel molds are used, mineral oil will also be needed to lightly coat the inside surface of the mold and keep the concrete from sticking to the mold.

Use on a local area network or other network is not permitted.